  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC/DC
Rated voltage480V
Frequency0 - 60Hz
Rated current16A
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Width in number of modular spacings4
Pollution degree3
Over voltage category3
Release characteristicK
Current limiting class3
Number of protected poles4
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Connectable conductor cross section solid-core0 - 35mm²
Number of poles (total)4
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274337R0467 | SU204M-K16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC/DC

Rated voltage

480V

Frequency

0 .. 60Hz

Rated current

16A

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Pollution degree

3

Over voltage category

3

Release characteristic

K

Current limiting class

3

Number of protected poles

4

Additional equipment possible

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Connectable conductor cross section solid-core

0 .. 35mm²

Number of poles (total)

4

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.