Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu800A
Rated voltage240 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range undelayed short-circuit release800 - 8000A
Overload release current setting320.0 - 800A
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of poles3
Type of control elementToggle
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20
Power loss24W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA103040R1 | XT7L 800 Ekip Dip LIG In=800A 3p F F UL

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

800A

Rated voltage

240 .. 600V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range undelayed short-circuit release

800 .. 8000A

Overload release current setting

320.0 .. 800A

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of poles

3

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

Power loss

24W