Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- HAGER
Technical specifications
System configuration DC
No
System configuration IT
No
System configuration TN-C
No
System configuration TN
No
System configuration TN-C-S
No
System configuration TN-S
Yes
Number of conductors (without earthing)
4
System configuration other
No
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
20kA
System configuration TT
Yes
Nominal voltage AC
415V
Max. continuous voltage AC
275V
Voltage protection level
1.35kV
Max. PV-voltage
0V
Voltage protection level L-N
1.35kV
Max. overcurrent protection device, series connection (fuse)
80A
Max. overcurrent protection device, parallel connection (fuse)
125A
Voltage protection level N-PE
1.5kV
Integrated short-circuit protection
No
Max. conductor cross section flexible (fine-strand)
25mm²
Category type 2
Yes
Short-circuit breaking capacity (Isccr)
25kA
Max. conductor cross section solid (solid, stranded)
35mm²
Construction size
4 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
No
Leakage-current free
No
With remote signalling contact
No
Signalling at the device
Optic
Degree of protection (IP)
IP20
SPB440D

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- HAGER
Technical specifications
System configuration DC
System configuration IT
System configuration TN-C
System configuration TN
System configuration TN-C-S
System configuration TN-S
Number of conductors (without earthing)
4
System configuration other
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
20kA
System configuration TT
Nominal voltage AC
415V
Max. continuous voltage AC
275V
Voltage protection level
1.35kV
Max. PV-voltage
0V
Voltage protection level L-N
1.35kV
Max. overcurrent protection device, series connection (fuse)
80A
Max. overcurrent protection device, parallel connection (fuse)
125A
Voltage protection level N-PE
1.5kV
Integrated short-circuit protection
Max. conductor cross section flexible (fine-strand)
25mm²
Category type 2
Short-circuit breaking capacity (Isccr)
25kA
Max. conductor cross section solid (solid, stranded)
35mm²
Construction size
4 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
Leakage-current free
With remote signalling contact
Signalling at the device
Optic
Degree of protection (IP)
IP20