Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu63A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Rated voltage690 - 690V
Overload release current setting50 - 63A
Adjustment range undelayed short-circuit release378 - 630A
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitFrame clamp
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Number of poles3
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Type of control elementRocker lever
Motor drive integratedNo
Motor drive optionalNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS1-A63

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

63A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated voltage

690 .. 690V

Overload release current setting

50 .. 63A

Adjustment range undelayed short-circuit release

378 .. 630A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Frame clamp

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of poles

3

With integrated under voltage release

Position of connection for main current circuit

Front side

Complete device with protection unit

Type of control element

Rocker lever

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.