Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SIEMENS

Technical specifications

Current limiting class3
Release characteristicB
Degree of protection (IP)IP20
Pollution degree2
Rated insulation voltage Ui-99999V
Frequency50.0 - 50.0Hz
Suitable for flush-mounted installationNo
Voltage typeAC
Concurrently switching neutral conductorNo
Width in number of modular spacings1
Over voltage category3
Number of protected poles1P
Rated current16A
Built-in depth70.0mm
Rated voltage400V
Connectable conductor cross section solid-core0.75 - 25.0mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6.0kA
Ambient temperature during operating-25 - 45°C
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6.0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6.0kA
Connectable conductor cross section multi-wired0.75 - 25.0mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6.0kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5SL6116-6 | MCB 1-pole B16A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SIEMENS

Technical specifications

Current limiting class

3

Release characteristic

B

Degree of protection (IP)

IP20

Pollution degree

2

Rated insulation voltage Ui

-99999V

Frequency

50.0 .. 50.0Hz

Suitable for flush-mounted installation

Voltage type

AC

Concurrently switching neutral conductor

Width in number of modular spacings

1

Over voltage category

3

Number of protected poles

1P

Rated current

16A

Built-in depth

70.0mm

Rated voltage

400V

Connectable conductor cross section solid-core

0.75 .. 25.0mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6.0kA

Ambient temperature during operating

-25 .. 45°C

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6.0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6.0kA

Connectable conductor cross section multi-wired

0.75 .. 25.0mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6.0kA