Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Power loss2.7W
Rated fault current0.03A
Rated current16A
Leakage current typeA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Number of protected poles1
Rated voltage400V
Disconnection characteristicUndelayed
Voltage typeAC
Surge current capacity3kA
Current limiting class3
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Pollution degree2
Release characteristicB
With interlocking deviceNo
Built-in depth91mm
Over voltage category3
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001658R0001 | FS401E-B16/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Power loss

2.7W

Rated fault current

0.03A

Rated current

16A

Leakage current type

A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of protected poles

1

Rated voltage

400V

Disconnection characteristic

Undelayed

Voltage type

AC

Surge current capacity

3kA

Current limiting class

3

Frequency

50/60 Hz

Concurrently switching neutral conductor

Pollution degree

2

Release characteristic

B

With interlocking device

Built-in depth

91mm

Over voltage category

3

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.