Number of protected poles1
Number of poles (total)2
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Rated current25A
Rated insulation voltage Ui500V
Leakage current typeA
Current limiting class3
Power loss4.4W
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Surge current capacity3kA
Frequency50/60 Hz
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Voltage typeAC
Release characteristicB
Over voltage category3
Pollution degree2
With interlocking deviceNo
Concurrently switching neutral conductorNo
Built-in depth91mm
Width in number of modular spacings2
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Connectable conductor cross section solid-core- - -mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001660R0001 | FS401E-B25/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

2

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Rated current

25A

Rated insulation voltage Ui

500V

Leakage current type

A

Current limiting class

3

Power loss

4.4W

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Release characteristic

B

Over voltage category

3

Pollution degree

2

With interlocking device

Concurrently switching neutral conductor

Built-in depth

91mm

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²