Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Current limiting class3
Rated fault current0.03A
Rated current10A
Rated voltage400V
Surge current capacity3kA
Leakage current typeA
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Rated insulation voltage Ui500V
Frequency50/60 Hz
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity according to EN 610096kA
Power loss1.9W
Release characteristicC
Over voltage category3
With interlocking deviceNo
Width in number of modular spacings2
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Pollution degree2
Connectable conductor cross section solid-core- - -mm²
Flush-mounted installationNo
Built-in depth91mm
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001663R0001 | FS401E-C10/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Current limiting class

3

Rated fault current

0.03A

Rated current

10A

Rated voltage

400V

Surge current capacity

3kA

Leakage current type

A

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated insulation voltage Ui

500V

Frequency

50/60 Hz

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Power loss

1.9W

Release characteristic

C

Over voltage category

3

With interlocking device

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Anti-nuisance tripping version

Pollution degree

2

Connectable conductor cross section solid-core

- .. -mm²

Flush-mounted installation

Built-in depth

91mm

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.