Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Rated insulation voltage Ui500V
Rated current13A
Rated fault current0.03A
Current limiting class3
Rated short-circuit breaking capacity according to EN 610096kA
Leakage current typeA
Power loss2.3W
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Surge current capacity3kA
Disconnection characteristicUndelayed
Voltage typeAC
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Release characteristicC
With interlocking deviceNo
Over voltage category3
Pollution degree2
Flush-mounted installationNo
Width in number of modular spacings2
Built-in depth91mm
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001664R0001 | FS401E-C13/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated current

13A

Rated fault current

0.03A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Leakage current type

A

Power loss

2.3W

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Surge current capacity

3kA

Disconnection characteristic

Undelayed

Voltage type

AC

Frequency

50/60 Hz

Concurrently switching neutral conductor

Release characteristic

C

With interlocking device

Over voltage category

3

Pollution degree

2

Flush-mounted installation

Width in number of modular spacings

2

Built-in depth

91mm

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C