Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Number of poles (total)2
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Power loss5.6W
Rated current32A
Voltage typeAC
Rated short-circuit breaking capacity according to EN 610096kA
Leakage current typeA
Disconnection characteristicUndelayed
Surge current capacity3kA
Frequency50/60 Hz
Rated fault current0.03A
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Current limiting class3
Concurrently switching neutral conductorNo
Width in number of modular spacings2
With interlocking deviceNo
Release characteristicC
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Pollution degree2
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core- - -mm²
Built-in depth91mm
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001668R0001 | FS401E-C32/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

2

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Power loss

5.6W

Rated current

32A

Voltage type

AC

Rated short-circuit breaking capacity according to EN 61009

6kA

Leakage current type

A

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Frequency

50/60 Hz

Rated fault current

0.03A

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Current limiting class

3

Concurrently switching neutral conductor

Width in number of modular spacings

2

With interlocking device

Release characteristic

C

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Pollution degree

2

Anti-nuisance tripping version

Connectable conductor cross section solid-core

- .. -mm²

Built-in depth

91mm

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.