Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Number of protected poles1
Rated fault current0.03A
Leakage current typeA
Rated current20A
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity according to EN 6100910kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Surge current capacity3kA
Power loss3W
Frequency50/60 Hz
Pollution degree2
Release characteristicB
Over voltage category3
With interlocking deviceNo
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Built-in depth91mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001673R0001 | FS401M-B20/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of protected poles

1

Rated fault current

0.03A

Leakage current type

A

Rated current

20A

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Power loss

3W

Frequency

50/60 Hz

Pollution degree

2

Release characteristic

B

Over voltage category

3

With interlocking device

Concurrently switching neutral conductor

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Built-in depth

91mm