Technical specifications

Number of protected poles1
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Rated current32A
Number of poles (total)2
Rated insulation voltage Ui500V
Rated fault current0.03A
Leakage current typeA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Frequency50/60 Hz
Power loss5.6W
Disconnection characteristicUndelayed
Surge current capacity3kA
Voltage typeAC
Concurrently switching neutral conductorNo
Over voltage category3
Release characteristicB
Built-in depth91mm
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core- - -mm²
Width in number of modular spacings2
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Pollution degree2
Flush-mounted installationNo
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001675R0001 | FS401M-B32/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Rated current

32A

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Leakage current type

A

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Frequency

50/60 Hz

Power loss

5.6W

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Voltage type

AC

Concurrently switching neutral conductor

Over voltage category

3

Release characteristic

B

Built-in depth

91mm

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

- .. -mm²

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

2

Flush-mounted installation

With interlocking device