Technical specifications

Number of poles (total)2
Number of protected poles1
Rated voltage415V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current16A
Rated fault current0.03A
Leakage current typeA
Rated short-circuit breaking capacity according to IEC 60947-225kA
Frequency50/60 Hz
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Power loss2.7W
Surge current capacity3kA
Disconnection characteristicUndelayed
Voltage typeAC
Concurrently switching neutral conductorNo
Release characteristicC
Pollution degree2
Over voltage category3
With interlocking deviceNo
Ambient temperature during operating-25 - 60°C
Built-in depth91mm
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Flush-mounted installationNo
Connectable conductor cross section solid-core- - -mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001679R0001 | FS401M-C16/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Rated fault current

0.03A

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Frequency

50/60 Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

2.7W

Surge current capacity

3kA

Disconnection characteristic

Undelayed

Voltage type

AC

Concurrently switching neutral conductor

Release characteristic

C

Pollution degree

2

Over voltage category

3

With interlocking device

Ambient temperature during operating

-25 .. 60°C

Built-in depth

91mm

Width in number of modular spacings

2

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.