Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated current20A
Rated fault current0.1A
Current limiting class3
Rated insulation voltage Ui500V
Number of protected poles1
Rated voltage415V
Leakage current typeA
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-215kA
Power loss3W
Surge current capacity3kA
Disconnection characteristicUndelayed
Voltage typeAC
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorNo
With interlocking deviceNo
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Built-in depth91mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001687R0001 | FS401M-C20/0.1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated current

20A

Rated fault current

0.1A

Current limiting class

3

Rated insulation voltage Ui

500V

Number of protected poles

1

Rated voltage

415V

Leakage current type

A

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Power loss

3W

Surge current capacity

3kA

Disconnection characteristic

Undelayed

Voltage type

AC

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Width in number of modular spacings

2

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Built-in depth

91mm