Technical specifications

Rated current6A
Rated short-circuit breaking capacity according to IEC 60947-225kA
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Number of poles (total)2
Surge current capacity3kA
Disconnection characteristicUndelayed
Voltage typeAC
Leakage current typeF
Rated impulse withstand voltage Uimp4kV
Frequency50/60 Hz
Rated insulation voltage Ui500V
Rated voltage400V
Number of protected poles1
Rated fault current0.03A
Power loss1.9W
With interlocking deviceNo
Release characteristicB
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree2
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core- - -mm²
Degree of protection (IP)IP20
Built-in depth91mm
Width in number of modular spacings2
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001690R0001 | FS401MK-B6/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of poles (total)

2

Surge current capacity

3kA

Disconnection characteristic

Undelayed

Voltage type

AC

Leakage current type

F

Rated impulse withstand voltage Uimp

4kV

Frequency

50/60 Hz

Rated insulation voltage Ui

500V

Rated voltage

400V

Number of protected poles

1

Rated fault current

0.03A

Power loss

1.9W

With interlocking device

Release characteristic

B

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

- .. -mm²

Degree of protection (IP)

IP20

Built-in depth

91mm

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²