Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage415V
Rated insulation voltage Ui500V
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated current10A
Rated fault current0.03A
Number of protected poles1
Leakage current typeF
Current limiting class3
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Power loss1.9W
Rated short-circuit breaking capacity according to IEC 60947-225kA
Surge current capacity3kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
With interlocking deviceNo
Concurrently switching neutral conductorNo
Pollution degree2
Width in number of modular spacings2
Built-in depth91mm
Over voltage category3
Degree of protection (IP)IP20
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core- - -mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001698R0001 | FS401MK-C10/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated current

10A

Rated fault current

0.03A

Number of protected poles

1

Leakage current type

F

Current limiting class

3

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Power loss

1.9W

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Surge current capacity

3kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

With interlocking device

Concurrently switching neutral conductor

Pollution degree

2

Width in number of modular spacings

2

Built-in depth

91mm

Over voltage category

3

Degree of protection (IP)

IP20

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.