Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage415V
Rated current13A
Rated fault current0.03A
Number of poles (total)2
Leakage current typeF
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Number of protected poles1
Power loss2.3W
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-225kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Frequency50/60 Hz
Surge current capacity3kA
Voltage typeAC
Release characteristicC
With interlocking deviceNo
Pollution degree2
Over voltage category3
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 60°C
Built-in depth91mm
Flush-mounted installationNo
Width in number of modular spacings2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001699R0001 | FS401MK-C13/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Rated current

13A

Rated fault current

0.03A

Number of poles (total)

2

Leakage current type

F

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

1

Power loss

2.3W

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Frequency

50/60 Hz

Surge current capacity

3kA

Voltage type

AC

Release characteristic

C

With interlocking device

Pollution degree

2

Over voltage category

3

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 60°C

Built-in depth

91mm

Flush-mounted installation

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor