Technical specifications

Number of poles (total)2
Number of protected poles1
Rated insulation voltage Ui500V
Rated voltage415V
Rated current32A
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Leakage current typeF
Current limiting class3
Rated short-circuit breaking capacity according to EN 6100910kA
Power loss5.6W
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Surge current capacity3kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorNo
Over voltage category3
With interlocking deviceNo
Width in number of modular spacings2
Built-in depth91mm
Flush-mounted installationNo
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 60°C
Pollution degree2
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core- - -mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001703R0001 | FS401MK-C32/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated voltage

415V

Rated current

32A

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Leakage current type

F

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

5.6W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

Over voltage category

3

With interlocking device

Width in number of modular spacings

2

Built-in depth

91mm

Flush-mounted installation

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 60°C

Pollution degree

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

- .. -mm²