Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated insulation voltage Ui500V
Rated voltage415V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.3A
Leakage current typeF
Power loss2.3W
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-225kA
Rated current13A
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Voltage typeAC
Frequency50/60 Hz
Surge current capacity3kA
Concurrently switching neutral conductorNo
Release characteristicC
Built-in depth91mm
Flush-mounted installationNo
Degree of protection (IP)IP20
Pollution degree2
Connectable conductor cross section solid-core- - -mm²
Anti-nuisance tripping versionNo
Width in number of modular spacings2
Ambient temperature during operating-25 - 60°C
With interlocking deviceNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001706R0001 | FS401MK-C13/0.3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated voltage

415V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Leakage current type

F

Power loss

2.3W

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Rated current

13A

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Voltage type

AC

Frequency

50/60 Hz

Surge current capacity

3kA

Concurrently switching neutral conductor

Release characteristic

C

Built-in depth

91mm

Flush-mounted installation

Degree of protection (IP)

IP20

Pollution degree

2

Connectable conductor cross section solid-core

- .. -mm²

Anti-nuisance tripping version

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 60°C

With interlocking device

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.