  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated voltage415V
Frequency50/60 Hz
Rated insulation voltage Ui500V
Rated fault current0.3A
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated current25A
Disconnection characteristicUndelayed
Current limiting class3
Voltage typeAC
Leakage current typeF
Surge current capacity3kA
Rated impulse withstand voltage Uimp4kV
Power loss4.4W
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Over voltage category3
With interlocking deviceNo
Pollution degree2
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Built-in depth91mm
Release characteristicC
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001709R0001 | FS401MK-C25/0.3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated voltage

415V

Frequency

50/60 Hz

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated current

25A

Disconnection characteristic

Undelayed

Current limiting class

3

Voltage type

AC

Leakage current type

F

Surge current capacity

3kA

Rated impulse withstand voltage Uimp

4kV

Power loss

4.4W

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Over voltage category

3

With interlocking device

Pollution degree

2

Width in number of modular spacings

2

Concurrently switching neutral conductor

Flush-mounted installation

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Built-in depth

91mm

Release characteristic

C

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.