Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Rated voltage400V
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Leakage current typeF
Number of poles (total)4
Power loss7.5W
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Rated current20A
Rated fault current0.03A
Frequency50/60 Hz
Surge current capacity3kA
Voltage typeAC
Current limiting class3
Concurrently switching neutral conductorNo
With interlocking deviceNo
Pollution degree2
Width in number of modular spacings4
Over voltage category3
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Built-in depth91mm
Connectable conductor cross section solid-core- - -mm²
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Release characteristicB
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001715R0001 | FS403M-B20/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Rated voltage

400V

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Leakage current type

F

Number of poles (total)

4

Power loss

7.5W

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated current

20A

Rated fault current

0.03A

Frequency

50/60 Hz

Surge current capacity

3kA

Voltage type

AC

Current limiting class

3

Concurrently switching neutral conductor

With interlocking device

Pollution degree

2

Width in number of modular spacings

4

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Built-in depth

91mm

Connectable conductor cross section solid-core

- .. -mm²

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Release characteristic

B