Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Rated fault current0.03A
Power loss7.5W
Rated current20A
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Number of protected poles3
Rated short-circuit breaking capacity according to IEC 60947-215kA
Leakage current typeA
Rated insulation voltage Ui500V
Voltage typeAC
Number of poles (total)4
Surge current capacity3kA
Rated voltage415V
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Frequency50/60 Hz
Rated short-circuit breaking capacity according to EN 6100910kA
Release characteristicC
Pollution degree2
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Width in number of modular spacings4
Connectable conductor cross section solid-core- - -mm²
Degree of protection (IP)IP20
Built-in depth91mm
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001729R0001 | FS403M-C20/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Rated fault current

0.03A

Power loss

7.5W

Rated current

20A

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Number of protected poles

3

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Leakage current type

A

Rated insulation voltage Ui

500V

Voltage type

AC

Number of poles (total)

4

Surge current capacity

3kA

Rated voltage

415V

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to EN 61009

10kA

Release characteristic

C

Pollution degree

2

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Width in number of modular spacings

4

Connectable conductor cross section solid-core

- .. -mm²

Degree of protection (IP)

IP20

Built-in depth

91mm

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

With interlocking device

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.