Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Rated insulation voltage Ui500V
Rated fault current0.1A
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Rated voltage415V
Rated current6A
Current limiting class3
Leakage current typeA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Voltage typeAC
Power loss5.3W
Rated short-circuit breaking capacity according to IEC 60947-225kA
Rated short-circuit breaking capacity according to EN 6100910kA
Surge current capacity3kA
Frequency50/60 Hz
Pollution degree2
Ambient temperature during operating-25 - 60°C
Release characteristicC
Built-in depth91mm
With interlocking deviceNo
Width in number of modular spacings4
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001732R0001 | FS403M-C6/0.1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Rated insulation voltage Ui

500V

Rated fault current

0.1A

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Rated voltage

415V

Rated current

6A

Current limiting class

3

Leakage current type

A

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Voltage type

AC

Power loss

5.3W

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Surge current capacity

3kA

Frequency

50/60 Hz

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Release characteristic

C

Built-in depth

91mm

With interlocking device

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.