Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles3
Current limiting class3
Number of poles (total)4
Rated short-circuit breaking capacity according to EN 6100910kA
Rated insulation voltage Ui500V
Rated voltage415V
Rated impulse withstand voltage Uimp4kV
Rated current10A
Leakage current typeA
Rated fault current0.1A
Power loss4.9W
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Surge current capacity3kA
Voltage typeAC
Frequency50/60 Hz
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to IEC 60947-225kA
Concurrently switching neutral conductorNo
Release characteristicC
Ambient temperature during operating-25 - 60°C
Built-in depth91mm
Over voltage category3
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Pollution degree2
With interlocking deviceNo
Width in number of modular spacings4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001733R0001 | FS403M-C10/0.1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Current limiting class

3

Number of poles (total)

4

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated insulation voltage Ui

500V

Rated voltage

415V

Rated impulse withstand voltage Uimp

4kV

Rated current

10A

Leakage current type

A

Rated fault current

0.1A

Power loss

4.9W

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

3kA

Voltage type

AC

Frequency

50/60 Hz

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Concurrently switching neutral conductor

Release characteristic

C

Ambient temperature during operating

-25 .. 60°C

Built-in depth

91mm

Over voltage category

3

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Pollution degree

2

With interlocking device

Width in number of modular spacings

4