Number of poles (total)4
Rated insulation voltage Ui500V
Number of protected poles3
Rated current20A
Rated voltage415V
Rated fault current0.1A
Rated impulse withstand voltage Uimp4kV
Leakage current typeA
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity according to EN 6100910kA
Power loss7.5W
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Voltage typeAC
Frequency50/60 Hz
Disconnection characteristicUndelayed
Surge current capacity3kA
Release characteristicC
With interlocking deviceNo
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Built-in depth91mm
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core- - -mm²
Over voltage category3
Connectable conductor cross section multi-wired0.75 - 25mm²
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001736R0001 | FS403M-C20/0.1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated current

20A

Rated voltage

415V

Rated fault current

0.1A

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

7.5W

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Voltage type

AC

Frequency

50/60 Hz

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Release characteristic

C

With interlocking device

Width in number of modular spacings

4

Concurrently switching neutral conductor

Anti-nuisance tripping version

Flush-mounted installation

Built-in depth

91mm

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

- .. -mm²

Over voltage category

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.