Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Number of protected poles3
Rated voltage415V
Rated insulation voltage Ui500V
Leakage current typeF
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Rated current6A
Rated fault current0.3A
Power loss5.3W
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-225kA
Disconnection characteristicUndelayed
Frequency50/60 Hz
Surge current capacity3kA
Voltage typeAC
Concurrently switching neutral conductorNo
With interlocking deviceNo
Ambient temperature during operating-25 - 60°C
Over voltage category3
Pollution degree2
Flush-mounted installationNo
Width in number of modular spacings4
Built-in depth91mm
Release characteristicC
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core- - -mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001753R0001 | FS403MK-C6/0.3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Number of protected poles

3

Rated voltage

415V

Rated insulation voltage Ui

500V

Leakage current type

F

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated current

6A

Rated fault current

0.3A

Power loss

5.3W

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Disconnection characteristic

Undelayed

Frequency

50/60 Hz

Surge current capacity

3kA

Voltage type

AC

Concurrently switching neutral conductor

With interlocking device

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Pollution degree

2

Flush-mounted installation

Width in number of modular spacings

4

Built-in depth

91mm

Release characteristic

C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Anti-nuisance tripping version

Connectable conductor cross section solid-core

- .. -mm²