Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles-
Rated voltage240V
Rated insulation voltage Ui-V
Rated current-A
Leakage current typeF
Rated fault current-A
Current limiting class3
Rated short-circuit breaking capacity according to EN 61009-kA
Power loss-W
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Surge current capacity-kA
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Number of poles (total)-
Concurrently switching neutral conductorNo
Release characteristicC
Over voltage category-
Width in number of modular spacings-
Pollution degree-
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Connectable conductor cross section solid-core- - -mm²
Built-in depth-mm
With interlocking deviceNo
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001767R0001 | FS402MK-C6/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

-

Rated voltage

240V

Rated insulation voltage Ui

-V

Rated current

-A

Leakage current type

F

Rated fault current

-A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

-kA

Power loss

-W

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Surge current capacity

-kA

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Number of poles (total)

-

Concurrently switching neutral conductor

Release characteristic

C

Over voltage category

-

Width in number of modular spacings

-

Pollution degree

-

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

Built-in depth

-mm

With interlocking device

Ambient temperature during operating

-25 .. 60°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.