Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicOther
Rated current125A
Number of poles (total)4
Rated voltage-V
Rated insulation voltage Ui1500V
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency0 - 0Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
Current limiting class3
Flush-mounted installationNo
Power loss37.6W
Over voltage category3
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Width in number of modular spacings6
Pollution degree2
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 50mm²
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001903R0001 | S804S-UCK125-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

Other

Rated current

125A

Number of poles (total)

4

Rated voltage

-V

Rated insulation voltage Ui

1500V

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

0 .. 0Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Current limiting class

3

Flush-mounted installation

Power loss

37.6W

Over voltage category

3

Additional equipment possible

Concurrently switching neutral conductor

Width in number of modular spacings

6

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 50mm²

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.