Technical specifications

Built-in depth82.5mm
Release characteristicOther
Rated insulation voltage Ui1500V
Rated voltage-V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated current125A
Current limiting class3
Number of poles (total)4
Frequency0 - 0Hz
Rated impulse withstand voltage Uimp8kV
Power loss37.6W
Number of protected poles4
Voltage typeOther
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree2
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 50mm²
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²
Width in number of modular spacings6
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001904R0001 | S804S-UCB125-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

Other

Rated insulation voltage Ui

1500V

Rated voltage

-V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated current

125A

Current limiting class

3

Number of poles (total)

4

Frequency

0 .. 0Hz

Rated impulse withstand voltage Uimp

8kV

Power loss

37.6W

Number of protected poles

4

Voltage type

Other

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

2

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 50mm²

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Width in number of modular spacings

6

Ambient temperature during operating

-25 .. 60°C