  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82mm
Release characteristicB
Number of poles (total)1
Number of protected poles1
Rated voltage230V
Rated insulation voltage Ui440V
Rated current50A
Power loss4.3W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Voltage typeOther
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Concurrently switching neutral conductorNo
Over voltage category3
Additional equipment possibleYes
Width in number of modular spacings1
Pollution degree4
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS551001R0505 | S401E-B50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82mm

Release characteristic

B

Number of poles (total)

1

Number of protected poles

1

Rated voltage

230V

Rated insulation voltage Ui

440V

Rated current

50A

Power loss

4.3W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Voltage type

Other

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Width in number of modular spacings

1

Pollution degree

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof