Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82mm
Release characteristicC
Rated current13A
Number of protected poles2
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Voltage typeOther
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Power loss3.8W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree4
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings2
Explosion-proofNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS552001R0134 | S402E-C13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82mm

Release characteristic

C

Rated current

13A

Number of protected poles

2

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Voltage type

Other

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Power loss

3.8W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

4

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

2

Explosion-proof

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.