Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Release characteristicB
Rated current16A
Number of poles (total)2
Built-in depth82mm
Rated voltage400V
Rated insulation voltage Ui440V
Voltage typeOther
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Flush-mounted installationNo
Power loss3.8W
Over voltage category3
Degree of protection (IP)IP20
Width in number of modular spacings2
Additional equipment possibleYes
Pollution degree4
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS552001R0165 | S402E-B16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Release characteristic

B

Rated current

16A

Number of poles (total)

2

Built-in depth

82mm

Rated voltage

400V

Rated insulation voltage Ui

440V

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Flush-mounted installation

Power loss

3.8W

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Additional equipment possible

Pollution degree

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor