Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Release characteristicB
Current limiting class3
Voltage typeOther
Rated current40A
Built-in depth82mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Power loss8.4W
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree4
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Width in number of modular spacings2
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS552001R0405 | S402E-B40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Release characteristic

B

Current limiting class

3

Voltage type

Other

Rated current

40A

Built-in depth

82mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Power loss

8.4W

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²