  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Release characteristicB
Number of poles (total)3
Built-in depth82mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated current6A
Voltage typeOther
Flush-mounted installationNo
Power loss5.4W
Rated insulation voltage Ui440V
Current limiting class3
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Pollution degree4
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS553001R0065 | S403E-B6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Release characteristic

B

Number of poles (total)

3

Built-in depth

82mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated current

6A

Voltage type

Other

Flush-mounted installation

Power loss

5.4W

Rated insulation voltage Ui

440V

Current limiting class

3

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Pollution degree

4

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.