Technical specifications

Built-in depth69mm
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Number of protected poles1
Rated voltage230V
Rated current2A
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Current limiting class3
Frequency50 - 60Hz
Power loss3.6W
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Width in number of modular spacings2.0
Over voltage category3
Ambient temperature during operating-25 - 55°C
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251103R0025 | LS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Number of protected poles

1

Rated voltage

230V

Rated current

2A

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Current limiting class

3

Frequency

50 .. 60Hz

Power loss

3.6W

Flush-mounted installation

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Width in number of modular spacings

2.0

Over voltage category

3

Ambient temperature during operating

-25 .. 55°C

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible