Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicD
Number of poles (total)4
Rated current20A
Rated voltage400V
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Power loss9.2W
Current limiting class3
Flush-mounted installationNo
Over voltage category3
Pollution degree3
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Width in number of modular spacings4.0
Explosion-proofNo
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253103R0201 | LS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

D

Number of poles (total)

4

Rated current

20A

Rated voltage

400V

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Power loss

9.2W

Current limiting class

3

Flush-mounted installation

Over voltage category

3

Pollution degree

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Width in number of modular spacings

4.0

Explosion-proof

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.