Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)4
Built-in depth69mm
Rated current50A
Flush-mounted installationNo
Power loss13W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Frequency50 - 60Hz
Release characteristicB
Current limiting class3
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Voltage typeOther
Rated voltage400V
Rated insulation voltage Ui440V
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Over voltage category3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings4.0
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253103R0505 | LS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

4

Built-in depth

69mm

Rated current

50A

Flush-mounted installation

Power loss

13W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Frequency

50 .. 60Hz

Release characteristic

B

Current limiting class

3

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Voltage type

Other

Rated voltage

400V

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

4.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Pollution degree

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.