Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Built-in depth69mm
Release characteristicK
Power loss1.39W
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated current4A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Number of poles (total)1
Rated voltage220V
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Flush-mounted installationNo
Voltage typeOther
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Width in number of modular spacings1.0
Connectable conductor cross section solid-core0.75 - 35mm²
Pollution degree3
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 55°C
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271067R0337 | LS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Built-in depth

69mm

Release characteristic

K

Power loss

1.39W

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated current

4A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Number of poles (total)

1

Rated voltage

220V

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Flush-mounted installation

Voltage type

Other

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

1.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3