Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Release characteristicK
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated insulation voltage Ui440V
Rated voltage220V
Number of poles (total)1
Voltage typeOther
Rated current13A
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Current limiting class3
Frequency50 - 60Hz
Flush-mounted installationNo
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss2.29W
Pollution degree3
Width in number of modular spacings1.0
Over voltage category3
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271067R0447 | LS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Release characteristic

K

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated insulation voltage Ui

440V

Rated voltage

220V

Number of poles (total)

1

Voltage type

Other

Rated current

13A

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Current limiting class

3

Frequency

50 .. 60Hz

Flush-mounted installation

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

2.29W

Pollution degree

3

Width in number of modular spacings

1.0

Over voltage category

3

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Degree of protection (IP)

IP20