Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Number of poles (total)1
Number of protected poles1
Built-in depth69mm
Rated insulation voltage Ui440V
Rated current16A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated voltage220V
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Flush-mounted installationNo
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Power loss2.23W
Concurrently switching neutral conductorNo
Over voltage category3
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Pollution degree3
Width in number of modular spacings1.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271067R0467 | LS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Number of poles (total)

1

Number of protected poles

1

Built-in depth

69mm

Rated insulation voltage Ui

440V

Rated current

16A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

220V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Flush-mounted installation

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Power loss

2.23W

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Pollution degree

3

Width in number of modular spacings

1.0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.