  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current2A
Current limiting class3
Built-in depth69mm
Number of protected poles2
Number of poles (total)2
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss3.6W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Release characteristicB
Rated insulation voltage Ui440V
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree3
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings2.0
Degree of protection (IP)IP20
Additional equipment possibleYes
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272001R0025 | LS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

2A

Current limiting class

3

Built-in depth

69mm

Number of protected poles

2

Number of poles (total)

2

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

3.6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Release characteristic

B

Rated insulation voltage Ui

440V

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2.0

Degree of protection (IP)

IP20

Additional equipment possible

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.