Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current13A
Leakage current typeA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Current limiting class3
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated voltage240V
Power loss3.5W
Number of poles (total)2
Rated fault current0.03A
Number of protected poles1
Rated short-circuit breaking capacity according to IEC 60947-26kA
Surge current capacity-kA
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Release characteristicC
Ambient temperature during operating-25 - 55°C
Over voltage category3
With interlocking deviceNo
Width in number of modular spacings2
Built-in depth69mm
Degree of protection (IP)IP20
Pollution degree2
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core25 - 25mm²
Connectable conductor cross section multi-wired25 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255187R1134 | DS201

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

13A

Leakage current type

A

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Current limiting class

3

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated voltage

240V

Power loss

3.5W

Number of poles (total)

2

Rated fault current

0.03A

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Surge current capacity

-kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Frequency

50/60 Hz

Concurrently switching neutral conductor

Release characteristic

C

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

With interlocking device

Width in number of modular spacings

2

Built-in depth

69mm

Degree of protection (IP)

IP20

Pollution degree

2

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

25 .. 25mm²

Connectable conductor cross section multi-wired

25 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.