Details
- •Low-voltage industrial components
- •Frequency converter =< 1 kV
- •1 KOM
- •EATON
Technical specifications
DA1-32011FB-B66O | Frequency invertor 3x230/3x230VAC 2,2kW 10,5A IP66, Brake chopper, RFI filter,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
180 .. 264V
Number of HW-interfaces other
0
With optical interface
Number of phases output
3
Mains frequency
50/60 Hz
Number of phases input
3
Max. output voltage
250V
Max. output frequency
500Hz
Nominal output current I2N
10.5A
Max. output at quadratic load at rated output voltage
2.2kW
Max. output at linear load at rated output voltage
2.2kW
Power consumption
90.2W
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Number of analogue inputs
2
Number of digital inputs
5
Number of digital outputs
2
Relative symmetric net frequency tolerance
10%
Application in industrial area permitted
With control element
Application in domestic- and commercial area permitted
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for KNX
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for PROFINET IO
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for BACnet
Number of interfaces PROFINET
0
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP66
Degree of protection (NEMA)
4X
Height
257mm
Width
188mm
Depth
171.5mm
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0