Details
- •Low-voltage industrial components
- •Frequency converter =< 1 kV
- •1 KOM
- •EATON
Technical specifications
DA1-324D3FB-B6SO | Frequency invertor 3x230/3x230VAC 0,75kW 4,3A IP66, local control, Brake chopper,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
180 .. 264V
Number of HW-interfaces other
0
With optical interface
Number of phases input
3
Mains frequency
50/60 Hz
Number of phases output
3
Nominal output current I2N
4.3A
Max. output frequency
500Hz
Max. output voltage
250V
Max. output at quadratic load at rated output voltage
0.75kW
Max. output at linear load at rated output voltage
0.75kW
Relative symmetric net frequency tolerance
10%
Power consumption
39.75W
Number of analogue outputs
2
Relative symmetric net voltage tolerance
10%
Number of digital inputs
5
Number of digital outputs
2
Number of analogue inputs
2
With control element
Application in domestic- and commercial area permitted
Application in industrial area permitted
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Integrated breaking resistance
4-quadrant operation possible
With PC connection
Degree of protection (NEMA)
4X
Type of converter
U converter
Height
257mm
Degree of protection (IP)
IP66
Width
188mm
Depth
182mm
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS-Safety
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for KNX
Supporting protocol for Foundation Fieldbus
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Number of HW-interfaces serial TTY
0
Supporting protocol for SERCOS
Number of HW-interfaces RS-485
2
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for other bus systems
Supporting protocol for BACnet
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIsafe
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-232
0
Number of HW-interfaces parallel
0
Number of HW-interfaces industrial Ethernet