Details
- •Low-voltage industrial components
- •Frequency converter =< 1 kV
- •1 KOM
- •EATON
Technical specifications
DA1-34039FB-B66O | Frequency invertor 3x400/3x400VAC 18,5kW 39A IP66, Brake chopper, RFI filter,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of phases output
3
Max. output voltage
500V
Mains frequency
50/60 Hz
Mains voltage
342 .. 528V
Max. output frequency
500Hz
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
2
With control element
Power consumption
444W
Number of digital inputs
5
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Max. output at linear load at rated output voltage
18.5kW
Number of phases input
3
Max. output at quadratic load at rated output voltage
18.5kW
Nominal output current I2N
39A
Number of analogue outputs
2
Relative symmetric net frequency tolerance
10%
Application in industrial area permitted
Number of digital outputs
2
Application in domestic- and commercial area permitted
Number of HW-interfaces other
1
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP66
Degree of protection (NEMA)
4X
Height
360mm
Width
240mm
Depth
271mm
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Supporting protocol for BACnet
Number of interfaces PROFINET
1
Supporting protocol for other bus systems
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0