Technical specifications
DA1-34046FB-B66O | Frequency invertor 3x400/3x400VAC 22KW 46A IP66, Brake chopper, RFI filter, Oled,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
342 .. 528V
Number of HW-interfaces other
1
Mains frequency
50/60 Hz
Max. output frequency
500Hz
Number of phases output
3
Number of phases input
3
Max. output voltage
500V
Nominal output current I2N
46A
Max. output at quadratic load at rated output voltage
22kW
Relative symmetric net frequency tolerance
10%
Power consumption
506W
Max. output at linear load at rated output voltage
22kW
Number of digital outputs
2
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP66
Degree of protection (NEMA)
4X
Height
360mm
Width
240mm
Depth
271mm
Application in industrial area permitted
Relative symmetric net voltage tolerance
10%
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for TCP/IP
Supporting protocol for BACnet
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for SafetyBUS p
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Number of HW-interfaces RS-232
0
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Number of interfaces PROFINET
1
Supporting protocol for other bus systems
Number of HW-interfaces RS-485
2
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Number of digital inputs
5
Number of analogue inputs
2
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces USB
0
Number of analogue outputs
2
Supporting protocol for CAN
Supporting protocol for KNX
With control element
Supporting protocol for Data-Highway
Supporting protocol for LON
Application in domestic- and commercial area permitted
Supporting protocol for PROFIBUS
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0