DA1-35034NB-B6SO | Frequency invertor 3x575/3x575VAC 22KW 34A IP66, local control, Brake chopper,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
450 .. 660V
Number of HW-interfaces other
1
With optical interface
With PC connection
Number of phases input
3
Number of phases output
3
Mains frequency
50/60 Hz
Max. output frequency
500Hz
Max. output voltage
600V
Nominal output current I2N
34A
Max. output at quadratic load at rated output voltage
22kW
Max. output at linear load at rated output voltage
22kW
Power consumption
660W
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Number of analogue inputs
2
Number of digital outputs
2
Relative symmetric net frequency tolerance
10%
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP66
Degree of protection (NEMA)
4X
Height
360mm
Width
240mm
Depth
262.5mm
Number of digital inputs
5
Application in industrial area permitted
Application in domestic- and commercial area permitted
With control element
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for KNX
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for SUCONET
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces RS-422
0
Supporting protocol for PROFINET IO
Number of interfaces PROFINET
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-232
0
Supporting protocol for BACnet
Supporting protocol for CAN
Supporting protocol for other bus systems
Supporting protocol for PROFINET CBA
Supporting protocol for ASI
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for SafetyBUS p
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Number of HW-interfaces RS-485
2
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0