Details
- •Low-voltage industrial components
- •Frequency converter =< 1 kV
- •1 KOM
- •EATON
Technical specifications
DA1-356D5NB-B6SO | Frequency invertor 3x575/3x575VAC 4KW 6.5A IP66, local control, Brake chopper,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
450 .. 660V
Number of HW-interfaces other
0
With optical interface
With PC connection
Number of phases input
3
Mains frequency
50/60 Hz
Number of phases output
3
Max. output frequency
500Hz
Nominal output current I2N
6.5A
Max. output voltage
600V
Relative symmetric net frequency tolerance
10%
Max. output at quadratic load at rated output voltage
4kW
Max. output at linear load at rated output voltage
4kW
Power consumption
120W
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Number of analogue inputs
2
Number of digital outputs
2
With control element
Application in industrial area permitted
Number of digital inputs
5
Supporting protocol for TCP/IP
Application in domestic- and commercial area permitted
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP66
Degree of protection (NEMA)
4X
Height
257mm
Width
188mm
Depth
182mm
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Supporting protocol for other bus systems
Number of HW-interfaces USB
0
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces RS-485
2
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for LON
Supporting protocol for BACnet
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces parallel
0
Number of HW-interfaces industrial Ethernet
0