Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Rated control supply voltage Us at DC24 - 24V
Rated operation power at AC-3, 400 V0.06kW
Rated operation power at AC-3, 230 V, 3-phase0.04kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current Ie0.21A
Rated operation current at AC-3, 400 V0.25A
Overload release current setting0.25 - 0.25A
Power consumption2.6W
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50A
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact0
Temperature compensated overload protectionYes
Release classCLASS 10 A
Type of electrical connection of main circuitSpring clamp connection
Ambient temperature, upper operating limit55°C
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
With transformerNo
Rail mounting possibleNo
Number of command positions0
Coordination class according to IEC 60947-4-3Class 2
Suitable for emergency stopNo
Number of indicator lights0
External reset possibleNo
With fuseNo
Degree of protection (IP)IP20
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Supporting protocol for TCP/IPNo
Supporting protocol for DeviceNetNo
Width45mm
Height197mm
Depth95mm
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET IONo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-0,25-M7(24VDC)-PI | Motor-starter combination direct, 24V DC control, Ie=0.21A, Pmax=0.06kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

With short-circuit release

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Rated operation power at AC-3, 400 V

0.06kW

Rated operation power at AC-3, 230 V, 3-phase

0.04kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

0.21A

Rated operation current at AC-3, 400 V

0.25A

Overload release current setting

0.25 .. 0.25A

Power consumption

2.6W

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50A

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Release class

CLASS 10 A

Type of electrical connection of main circuit

Spring clamp connection

Ambient temperature, upper operating limit

55°C

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

With transformer

Rail mounting possible

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

Suitable for emergency stop

Number of indicator lights

0

External reset possible

With fuse

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet

Width

45mm

Height

197mm

Depth

95mm

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.