Technical specifications
MSC-D-0,4-M7(24VDC)/BBA | Motor-starter combination direct, 24V DC control, Ie=0.31A, Pmax=0.09kW,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
With short-circuit release
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for INTERBUS-Safety
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation power at AC-3, 230 V, 3-phase
0.06kW
Rated operation power at AC-3, 400 V
0.09kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
0.31A
Rated operation current at AC-3, 400 V
0.4A
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
200mm
Depth
154mm
Rail mounting possible
External reset possible
With transformer
Degree of protection (NEMA)
Other
Coordination class according to IEC 60947-4-3
Class 2
Suitable for emergency stop
Number of command positions
0
Number of indicator lights
0
With fuse
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for CAN
Degree of protection (IP)
IP20
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Overload release current setting
0.25 .. 0.4A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 400 V
50000A
Power consumption
2.6W
Number of auxiliary contacts as normally closed contact
0
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally open contact
1
Release class
CLASS 10 A
Temperature compensated overload protection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for LON